G60-12A (13.8V 3.3AïŒ Pb-Acid Battery Charger
|
Item |
Specification |
Remark |
1.Input |
Rating input voltage |
100~240Vac 50/60Hz |
|
Input voltage range |
90~264Vac |
|
Rating input current |
1.0Arms |
Input:100V Output:Full load |
Max input power |
60W |
Input:100V Output:Full load |
2.Output |
No load output voltage |
DC 2.37V |
Detection of battery voltage > 3V , start charging |
Output voltage range |
DC10.0~14.7V |
|
Suit with battery type |
12V Pb-Acid battery |
|
Charging current |
3.3A ±10% |
|
Charging voltage |
DC14.7V ±0.3V |
When the battery is vulcanized, the voltage rises to 18V to repair the battery |
Floating charge voltage |
DC13.2-13.8V |
ă |
Charge-end current |
â€0.6A±10% |
|
Timer |
>14V,Enter floating charge after 3 hours |
|
Max output power |
48.51W |
|
Ripple voltage |
â€147mV |
Full load |
Power LED |
Red |
Power on |
Charging LED |
All off |
No battery |
All on |
Finished |
All flashing |
Error |
Flashing one by one |
Charging |
Shorted |
Yes |
|
Reversed |
Yes |
|
Efficiency |
â„82% |
Full load @220V |
3.Environment |
Operate temperature |
-10 ~ +40â |
ă |
Operate humidity |
< +90% |
Relative humidity |
Storage temperature |
-40 ~ +70â |
|
Storage humidity |
0 ~ +95% |
Relative humidity |
Cooling |
Natural |
|
Vibration resistance |
5MM/50HZ/600S |
Non-operating condition |
Impact resistance |
1 meter drop test 3 times |
Non-operating condition |
4.Mechanical |
Weight |
270g |
|
Size |
127X67X38MM |
Casing only |
Connector |
Refer to order |
|
5.Safety |
Max. temperature rise |
< 40â on casing |
|
Safety approval |
CE/cTUVus/PSE/CCC |
|
MTBF |
30000H |
|
ESD |
8.0KV |
|
Hi-Pot Insulation |
i/p to o/p: 3000V (1 min) |
|