G1200-432277LiFePO4 Battery Charger for 16Cells 38.4V Li-Fe Battery
- Specification
- Input: 90~264V
- Output: 43.2V 27.7A
- Charge Process: Pre-chargeã€CCã€CV and Cut-off(Four stages)
- Charger Indicator: Digital LCD display voltage,current and charging process
- Output Protections: OVPã€OCPã€OTPã€Shorted and Reversed
- Safety Approval: CE cTUVus CB
- Size: 265X134X60MM/2.5Kg
- Industry: Power Toolsã€Security System
SPECIFICATION(Li-Fe battery charger)
MODEL |
G1200-432277 |
|||
OUTPUT |
Charge voltage |
43.2V±1% |
||
Charge voltage range |
30.0-43.2V |
|||
Charge current |
27.7A±10% |
|||
Pre-charge current |
5.54A±10% |
|||
Charge-end current |
≤2.77A ±10% |
|||
Rated power |
1196.64W |
|||
Recommended battery capacity Note.3 |
30 - 100Ah |
|||
Leakage current from battery (Typ.) |
≤1mA |
|||
CHARGE INDICATOR |
LCD display |
Display voltage(Display error ± 2%), current(Display error ± 6%), capacity |
||
COMMUNICATION FUNCTION |
USB / CAN / 485 Note.1 |
The battery type (Lead acid, Lithium battery,LiFePO4 battery), charging voltage and charging current can be set by USB interface, Communication with external devices via CAN or RS485. |
||
INPUT |
Rated input voltage |
100 - 240VAC 50 / 60Hz |
||
Input voltage range Note.4 |
90 - 264VAC |
|||
Power factor (Typ.) |
PF>0. 96 @full load |
|||
Input current (Typ.) |
14A@100VAC |
|||
Inrush current (Typ.) |
Cold start 75A @230VAC |
|||
Standby input power |
< 6W |
|||
Efficiency (Typ.) |
92% |
|||
PROTECTION |
Short circuit Note.5 |
Protection type : Shut down output |
||
Over voltage |
>3.7V*N |
|||
Reverse polarity |
By internal relay |
|||
Over temperature |
Shut down output, recovers automatically after temperature goes down |
|||
ENVIRONMENT |
Working temperature |
-10 - +40℃ (Refer to " Derating Curve") |
||
Working humidity |
0 - 90% RH |
|||
Storage temperature, humidity |
-40 - +70℃, 0 - 95% RH |
|||
Cooling |
Fan convection |
|||
Vibration resistance |
10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes |
|||
SAFETY & EMC(Note.6) |
Max. temperature rise |
< 40℃ on casing |
||
Hi-Pot Insulation |
i/p to o/p: 3000V (1 min) |
|||
Safety standards |
IEC62368 |
|||
EMC Emission |
Parameter |
Standard |
Test Level I Note |
|
Conducted |
EN55032 FCC PART15 |
Class B |
||
Radiated |
EN55032 FCC PART15 |
Class B |
||
Harmonic Current |
EN61000-3-2 |
..... |
||
Voltage Flicker |
EN61000-3-3 |
..... |
||
EMC IMMUNITY |
EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11 |
|||
OTHERS |
MTBF |
30000H |
||
Dimension |
265*134*60mm (L*W*H) |
|||
Weight |
2500g |
|||
NOTE |
|