G600-168290 Lithium Smart Charger for 4Cells 14.8V Li-ion Battery
- Specification
- Input: 100~240V
- Output: 16.8V 29.0A
- Charge Process: Pre-chargeăCCăCV and cut-offïŒFour stagesïŒ
- Charger Indicator: Digital LCD display voltageïŒcurrent and charging process
- Output Protections: OVPăOCPăOTPăShortedăReversed
- Safety Approval: CE cTUVus CB
- Size: 240X117X66MM/1.5Kg
- Industry: Power ToolsăSecurity System
SPECIFICATION(Li-ion battery charger)
MODEL |
G600-168290 |
|||
OUTPUT |
Charge voltage |
16.8V±1% |
||
Charge voltage range |
10-16.8V |
|||
Charge current |
29.0A±10% |
|||
Pre-charge current |
5.8A±10% |
|||
Charge-end current |
â€2.9A ±20% |
|||
Rated power |
487.2W |
|||
Recommended battery capacity Note.3 |
60 - 200Ah |
|||
Leakage current from battery (Typ.) |
â€1mA |
|||
CHARGE INDICATOR |
LCD display |
Display voltage(Display error ± 2%), current(Display error ± 6%), capacity |
||
COMMUNICATION FUNCTION |
USB / CAN / 485 Note.1 |
The battery type (Lead acid, Lithium battery,LiFePO4 battery), charging voltage and charging current can be set by USB interface, Communication with external devices via CAN or RS485. |
||
INPUT |
Rated input voltage |
100 - 240VAC 50 / 60Hz |
||
Input voltage range Note.4 |
90 - 264VAC |
|||
Power factor (Typ.) |
PF>0. 98 @AC100V, full load |
|||
Input current (Typ.) |
6.8A@100VAC |
|||
Inrush current (Typ.) |
Cold start 75A @230VAC |
|||
Standby input power |
< 2.5W |
|||
Efficiency (Typ.) |
90% |
|||
PROTECTION |
Short circuit Note.5 |
Protection type : Shut down output |
||
Over voltage |
>4.35V*N |
|||
Reverse polarity |
By internal relay |
|||
Over temperature |
Shut down output, recovers automatically after temperature goes down |
|||
ENVIRONMENT |
Working temperature |
-10 - +40â (Refer to " Derating Curve") |
||
Working humidity |
0 - 90% RH |
|||
Storage temperature, humidity |
-40 - +70â, 0 - 95% RH |
|||
Cooling |
Fan convection |
|||
Vibration resistance |
10 - 50Hz, 2G 10min. 1cycle, 60min. each along X, Y, Z axes |
|||
SAFETY & EMC (Note.6) |
Max. temperature rise |
< 40â on casing |
||
Hi-Pot Insulation |
i/p to o/p: 3000V (1 min) |
|||
Safety standards |
IEC62368-1 |
|||
EMC Emission |
Parameter |
Standard |
Test Level I Note |
|
Conducted |
EN55032 FCC PART15 |
Class B |
||
Radiated |
EN55032 FCC PART15 |
Class B |
||
Harmonic Current |
EN61000-3-2 |
..... |
||
Voltage Flicker |
EN61000-3-3 |
..... |
||
EMC IMMUNITY |
EN61000-4-2ïŒEN61000-4-3ïŒEN61000-4-4ïŒEN61000-4-5ïŒEN61000-4-6ïŒEN61000-4-8ïŒEN61000-4-11 |
|||
OTHERS |
MTBF |
30000H |
||
Dimension |
240*117*66mm (L*W*H) |
|||
Weight |
1500g |
|||
NOTE |
|