battery charger, car battery charger, lead acid battery charger, lipo charger, li-ion battery charger, nimh battery charger

G600-480125 High power adapter is suitable for monitoring system and radio system

  • Specification
  • Input: 100~240V
  • Output: 48.0V 12.5A
  • Charge Process:
  • Charger Indicator:
  • Safety Approval: CE cTUVus CB
  • Size: 240X117X66MM/1.5Kg
  • Industry: Monitoring system and Radio system
G600-480125 High power adapter is suitable for monitoring system and radio system

SPECIFICATION

MODEL

G600-480125

OUTPUT

Voltage  

48V±5%

current

0-12.5A

Rated power

600W

Voltage regulation

1%

Load regulation

5%

Start-up time

1000mS(Input:115VAC  Output:Full load)

Rise time

30mS (Input:115VAC  Output:Full load)

Hold time

15mS (Input:115VAC  Output:Full load)

Ripple voltage

<output voltage*1% (20MHz ,AC coupling mode, connected in parallel with 0.1uf ceramic capacitor and 47uf electrolytic capacitor)

LCD display

Display voltage(Display error ± 2%), current(Display error ± 6%)

INPUT

Rated input voltage

100 - 240VAC  50 / 60Hz

Input voltagerange Note.2

90 - 264VAC

Power factor (Typ.)

PF>0. 98  @AC100V,Full load

Input current (Typ.)

6.8A@100VAC   

Inrush current  (Typ.)

75A/230VAC (cold start)

Standby input power

<5W

Efficiency (Typ.)

92%

PROTECTION

Short circuit                  

Protection type : Shut down output

Over voltage

Protection type : Shut down output

Over current

Protection type : Shut down output  (110-160%)

Over temperature

Protection type : Shut down output

ENVIRONMENT

Working temperature

-10 - +40℃ (Refer to " Derating Curve")

Working humidity

0 - 90% RH

Storagetemperature,humidity

-40 - +70℃, 0 - 95% RH

Cooling

 Natural convection

Vibration resistance

10-50Hz,2G10min.1cycle,60min.eachalongX,Y,Zaxes

SAFETY&EMC (Note.3)

Max. temperature rise

< 40℃ on casing

Hi-Pot Insulation

i/p to o/p: 3000V (1 min)

Safety standards

IEC62368-1

EMC Emission

Parameter

Standard

Test Level I Note

Conducted

EN55032  FCC  PART15

Class B

Radiated

EN55032  FCC  PART15

Class B

Harmonic Current

EN61000-3-2

.....

Voltage Flicker

EN61000-3-3

.....

EMC IMMUNITY

EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11

OTHERS

MTBF

30000H

Dimension

240*117*66mm (L*W*H)

Weight

1500g

NOTE

  1. 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2.Derating may be needed under low input voltages. Please check the derating curve for more details.
  3. 3.The power unit is considered as an independent unit, but  the final equipment still need to re-confirm that the whole system complies    with the EMC directives.
Top