G300-240125 High Power Adapter for LED, Consumer Electronics

G300-240125

Input Voltage 100~240V
Output 24.0V 12.5A
Multi-protection OVP, OCP, OTP, SCP
Safety Approvals CB CE FCC CCC cTUVus PSE KC
Dimensions & Weight 220 x 105 x 43 mm / 1.3 kg
Applications LED, Consumer Electronics

SPECIFICATION

MODELG300-240125
OUTPUTVoltage24.0V±5%
current0-12.5A
Rated power300W
Voltage regulation1%
Load regulation5%
Start-up time300mS(Input:115VAC Output: Full load)
Rise time30mS (Input:115VAC Output: Full load)
Hold time20mS (Input:115VAC Output: Full load)
Ripple voltage<output voltage*1% (20MHz ,AC coupling mode, connected in parallel with 0.1uf ceramic capacitor and 47uf electrolytic capacitor)
Power LEDRed
INPUTRated input voltage100 - 240VAC 50 / 60Hz
Input voltage range Note.290 - 264VAC
Power factor (Typ.)PF>0. 98 @Full load,Input:115VAC ;PF>0. 94 @Full load,Input:230VAC
Input current (Typ.)4.5A@100VAC
Inrush current (Typ.)75A/230VAC (cold start)
Standby input power<0.2W
Efficiency (Typ.)95%
PROTECTIONShort circuitProtection type : Shut down output
Over voltageProtection type : Shut down output
Over currentProtection type : Shut down output (110-160%)
Over temperatureProtection type : Shut down output
ENVIRONMENTWorking temperature-10 - +40℃ (Refer to " Derating Curve")
Working humidity0 - 90% RH
Storage temperature, humidity-40 - +70℃, 0 - 95% RH
CoolingNatural convection
Vibration resistance10-50Hz,2G10min.1cycle,60min.eachalongX,Y,Zaxes
SAFETY&EMC
(Note.3)
Max. temperature rise< 40℃ on casing
Hi-Pot Insulationi/p to o/p: 3000V (1 min)
Safety approvalCE/CCC/cTUVus/CB
EMC EmissionParameterStandardTest Level I Note
ConductedEN55032 FCC PART15Class B
RadiatedEN55032 FCC PART15Class B
Harmonic CurrentEN61000-3-2.....
Voltage FlickerEN61000-3-3.....
EMC IMMUNITYEN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11
OTHERSMTBF30000H
Dimension220*105*43 (L*W*H)
Weight1300g
NOTE1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2.Derating may be needed under low input voltages. Please check the derating curve for more details.
3.The power unit is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives.