G600-600100 600W High Power Adapter for Home Appliances

G600-600100

Input Voltage 100~240V
Output 60.0V 10.0A
Multi-protection OVP, OCP, OTP, SCP
Safety Approvals CE cTUVus CB
Dimensions & Weight 240 x 117 x 66 mm / 1.5 kg
Applications IT, Home Appliances

SPECIFICATION

MODELG600-600100
OUTPUTVoltage60V±5%
current0-10A
Rated power600W
Voltage regulation1%
Load regulation5%
Start-up time1000mS(Input:115VAC Output:Full load)
Rise time30mS (Input:115VAC Output:Full load)
Hold time15mS (Input:115VAC Output:Full load)
Ripple voltage<output voltage*1% (20MHz ,AC coupling mode, connected in parallel with 0.1uf ceramic capacitor and 47uf electrolytic capacitor)
LCD displayDisplay voltage(Display error ± 2%), current(Display error ± 6%)
INPUTRated input voltage100 - 240VAC 50 / 60Hz
Input voltagerange Note.290 - 264VAC
Power factor (Typ.)PF>0. 98 @AC100V,Full load
Input current (Typ.)6.8A@100VAC
Inrush current (Typ.)75A/230VAC (cold start)
Standby input power<5W
Efficiency (Typ.)93%
PROTECTIONShort circuitProtection type : Shut down output
Over voltageProtection type : Shut down output
Over currentProtection type : Shut down output (110-160%)
Over temperatureProtection type : Shut down output
ENVIRONMENTWorking temperature-10 - +40℃ (Refer to " Derating Curve")
Working humidity0 - 90% RH
Storagetemperature,humidity-40 - +70℃, 0 - 95% RH
CoolingNatural convection
Vibration resistance10-50Hz,2G10min.1cycle,60min.eachalongX,Y,Zaxes
SAFETY&EMC (Note.3)Max. temperature rise< 40℃ on casing
Hi-Pot Insulationi/p to o/p: 3000V (1 min)
Safety standardsIEC62368-1
EMC EmissionParameterStandardTest Level I Note
ConductedEN55032 FCC PART15Class B
RadiatedEN55032 FCC PART15Class B
Harmonic CurrentEN61000-3-2.....
Voltage FlickerEN61000-3-3.....
EMC IMMUNITYEN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6,EN61000-4-8,EN61000-4-11
OTHERSMTBF30000H
Dimension240*117*66mm (L*W*H)
Weight1500g
NOTE1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Derating may be needed under low input voltages. Please check the derating curve for more details.
3.The power unit is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives.